Keyboard shortcuts

Press ← or → to navigate between chapters

Press S or / to search in the book

Press ? to show this help

Press Esc to hide this help

Home | Documentation | Community support

Xunlink

Prerequisites

Device details

The steps below were tested on the TM-CP2B-P (V11), a model in the same series as the TM-CP2B linked above. The TM-CP2B-P is an industrial Linux gateway (Ubuntu 24.04) with a Mini PCIe slot for an optional SX1302-based LoRaWAN concentrator module, connected over SPI (/dev/spidev0.0).

Network connectivity

  • Ensure the gateway can reach the server running the ChirpStack Gateway Bridge (UDP port 1700).

Configuring the gateway

Build the concentrator HAL and packet forwarder

The SX1302 HAL source for the TM-CP2B series is provided by Xunlink on request. Please contact Xunlink through the product page linked above to obtain the download link.

Log in to the gateway (serial console or SSH) and run:

git clone <SX1302 HAL source URL provided by Xunlink>
cd sx1302
git checkout cp2b
make clean all
make -j8
cp tools/reset_lgw.sh util_chip_id/
cp tools/reset_lgw.sh packet_forwarder/
cp tools/reset_lgw.sh libloragw/

Read the gateway EUI

cd util_chip_id/
sudo ./chip_id

Note the EUI printed by chip_id. You need it when adding the gateway in ChirpStack.

Point the packet forwarder at ChirpStack

In packet_forwarder/, edit the global_conf.json.sx1250.<REGION> file that matches your module’s frequency band (tested with global_conf.json.sx1250.EU868), and set the gateway_conf section:

"gateway_ID": "<EUI from chip_id>",
"server_address": "<ChirpStack Gateway Bridge host>",
"serv_port_up": 1700,
"serv_port_down": 1700

Start the forwarder, passing the configuration file:

cd packet_forwarder/
sudo ./lora_pkt_fwd -c global_conf.json.sx1250.EU868

On units without a GPS module, a warning about /dev/ttyS0 appears at startup. This does not affect packet forwarding.

Adding the gateway to ChirpStack

  1. Go to Tenants -> Gateways and click Add gateway.
  2. Enter a name and the Gateway ID (EUI64) read with chip_id.
  3. Click Submit.

Verifying the connection

In Tenants -> Gateways, the gateway status should show Online.

(Tested with ChirpStack 4.20.0 on the TM-CP2B-P V11.)